No crank
Battery, cables, starter or a controller that is holding the start off.
Onsite generator repairs, servicing & maintenance across Gauteng
Mitsubishi diesel
Mitsubishi diesel engines in generator sets are serviced as diesels. This is not a vehicle workshop page.

Mitsubishi diesel engines in generator sets are serviced as diesels. This is not a vehicle workshop page.
No-start bookings are split on the phone where possible. A click with no crank is electrical. A crank with smoke and no run is fuel or a shutdown.
Maintenance is the practical fix for sets that fail only when an outage is long.
Supported Mitsubishi diesel generator sets are worked on across the capacities that match the machine on site, from the applications described above through to larger sets where the plate and the installation allow it. Engine, alternator, controller, kVA, phase, duty, hours and service history decide the work. A maximum kVA is not stated.
Fuel issues include stale diesel and blocked filters on sets that are only run for a monthly test.
Batteries and charging systems are checked because a monthly start can hide a charger that is doing nothing.
Cooling and electrical output are separate findings. A set can run and still be unsafe to leave on load if the temperature climbs.
Checked on the set. The finding decides the repair.
Battery, cables, starter or a controller that is holding the start off.
Fuel filters, air, a solenoid or injection delivery — proved in that order.
Breaker, AVR and alternator after the diesel is stable.
Temperature, oil pressure or a controller trip. The alarm is read before a reset.
ProService Generator Repairs is not described as an authorised Mitsubishi centre.
Parts are discussed after the fault is known.
Sets that sit and sets that run are not serviced as if they were the same job.
The visit is arranged from the location and the plate, not from a guessed suburb list.
Mitsubishi diesel visits are arranged across the major Gauteng areas.
Google Review
Top-tier mechanics for Mitsubishi diesel plants. They accurately diagnosed a failing turbocharger and replaced it before it could cause catastrophic engine damage.
Google Review
Preventative maintenance heroes for Mitsubishi.
Yes. Mitsubishi diesel engines in generator sets are serviced as diesels. This is not a vehicle workshop page.
A click with no crank is electrical: battery, terminals or the starter. A crank with smoke and no run is fuel or a shutdown. The two are not mixed on the first tests.
Yes. Sets that only run for a monthly test often suffer stale diesel and blocked filters. The fuel condition is checked before injectors are discussed.
Yes. A monthly start can hide a charger that is doing nothing. The battery is tested, and so is the charge path, so the next outage does not repeat the same no-crank.
Yes. A set can run and still be unsafe to leave on load if the temperature climbs. Coolant, airflow and load are checked. It should not be restarted repeatedly after a temperature shutdown.
Yes. Missing voltage is an AVR, breaker and alternator check once the engine runs. It is a different visit from a no-start.
Tell us if the Mitsubishi set starts and then shuts down. Call or WhatsApp ProService Generator Repairs on 082 057 4605.