No crank
Battery, cables, starter or a controller that is holding the start off.
Onsite generator repairs, servicing & maintenance across Gauteng
Lovol diesel
Lovol diesel generator sets are serviced for standby and commercial sites. The brand is treated as a genset visit: engine, canopy and controller.

Lovol diesel generator sets are serviced for standby and commercial sites. The brand is treated as a genset visit: engine, canopy and controller.
Starting problems after a long idle are fuel and battery. Both are tested. A new battery is not fitted to hide a fuel fault.
Preventative maintenance is the useful booking for a Lovol set that only runs in load shedding.
Supported Lovol diesel generator sets are worked on across the capacities that match the machine on site, from the applications described above through to larger sets where the plate and the installation allow it. Engine, alternator, controller, kVA, phase, duty, hours and service history decide the work. A maximum kVA is not stated.
Fuel-system issues include water in the diesel and filters that have never been changed. The tank is questioned when the second filter blocks too.
Cooling faults are dust and coolant level on canopy sets.
Output faults are recorded separately so the customer can see whether the engine or the alternator failed.
Checked on the set. The finding decides the repair.
Battery, cables, starter or a controller that is holding the start off.
Fuel filters, air, a solenoid or injection delivery — proved in that order.
Breaker, AVR and alternator after the diesel is stable.
Temperature, oil pressure or a controller trip. The alarm is read before a reset.
ProService Generator Repairs is not described as an authorised Lovol centre.
Parts are discussed after the fault is known.
Sets that sit and sets that run are not serviced as if they were the same job.
The visit is arranged from the location and the plate, not from a guessed suburb list.
Lovol diesel visits are arranged across the major Gauteng areas.
Google Review
They know the Lovol engines well. They fixed a sticky mechanical governor that was causing voltage spikes, protecting our sensitive office equipment from damage.
Google Review
Dependable Lovol fault finding.
Yes. Lovol diesel standby and commercial sets are serviced as a genset visit: engine, canopy and controller together.
Fuel and the battery are the usual pair. Both are tested. A new battery is not fitted to hide a fuel fault, and new fuel is not used to hide a flat battery.
Yes. Water and filters that have never been changed are common on sets that only run in outages. If a second filter blocks quickly, the tank is questioned.
Yes. Canopy sets collect dust on the radiator. Coolant level and airflow are checked when the set shuts down on temperature.
Yes. The report separates a diesel that will not run from a diesel that runs and makes no power. Output faults are the breaker and the AVR.
Yes. Preventative maintenance is the useful booking for a set that only runs when the supply fails. Oil, filters and the battery are the core of that visit.
Say how the set fails: no crank, no fire, or no power. Call or WhatsApp ProService Generator Repairs on 082 057 4605.