No crank
Battery, cables, starter or a controller that is holding the start off.
Onsite generator repairs, servicing & maintenance across Gauteng
Aksa diesel
Aksa diesel generator sets are serviced as standby machines for commercial sites. The controller brand on the set is recorded, because it is not always obvious from the canopy.

Aksa diesel generator sets are serviced as standby machines for commercial sites. The controller brand on the set is recorded, because it is not always obvious from the canopy.
Starting faults are the first question: does it crank. Fuel-system work follows a yes. Battery and starter work follows a no.
Maintenance is the right booking when the set is healthy and the concern is the next outage.
Supported Aksa diesel generator sets are worked on across the capacities that match the machine on site, from the applications described above through to larger sets where the plate and the installation allow it. Engine, alternator, controller, kVA, phase, duty, hours and service history decide the work. A maximum kVA is not stated.
Controller alarms are photographed. A maintenance alarm is not the same fault as a shutdown.
Output faults are voltage, breaker and AVR. A set that makes power and will not transfer is an ATS symptom.
Cooling and leaks are inspected with the canopy open.
Checked on the set. The finding decides the repair.
Battery, cables, starter or a controller that is holding the start off.
Fuel filters, air, a solenoid or injection delivery — proved in that order.
Breaker, AVR and alternator after the diesel is stable.
Temperature, oil pressure or a controller trip. The alarm is read before a reset.
ProService Generator Repairs is not described as an authorised Aksa centre.
Parts are discussed after the fault is known.
Sets that sit and sets that run are not serviced as if they were the same job.
The visit is arranged from the location and the plate, not from a guessed suburb list.
Aksa diesel visits are arranged across the major Gauteng areas.
Google Review
They quickly diagnosed a fuel lift pump failure on our Aksa generator and had the parts sourced instantly to prevent our business from shutting down.
Google Review
Rapid Aksa emergency repairs.
Yes. Aksa diesel standby sets for commercial sites are serviced and repaired. The controller brand on the set is recorded, because it is not always obvious from the canopy.
The useful question is whether it cranks. Fuel-system work follows a yes. Battery and starter work follows a no. Both answers can be given over the phone if you have tried the start.
Yes. Photograph the alarm text. A maintenance alarm is not the same fault as a shutdown, and clearing it without a cause is not the repair.
Yes. A set that makes power and will not transfer is an ATS symptom. A set that makes no voltage is an AVR or breaker symptom. They are not the same visit.
Yes. Maintenance is the right booking when the set is healthy and the concern is the next outage. Oil, filters, coolant and the battery are the usual items, matched to that machine.
Yes. Filters, contamination and delivery are checked when the engine cranks and will not fire. The tank is questioned if filters block repeatedly.
Send the alarm text if the controller is showing one. Call or WhatsApp ProService Generator Repairs on 082 057 4605.